Purnima, B. Valli and Ramu, G. and Ramachandran, D. (2023) First and Second Order Derivative Spectrophotometric Methods for Simultaneous Determination of Emtricitabine and Tenofovir Disoproxil Fumarate Tablets. In: Progress in Chemical Science Research Vol. 9. B P International, pp. 109-129. ISBN 978-81-19217-79-3
Full text not available from this repository.Abstract
Emtricitabine and tenofovir disoproxil fumarate in pure and tablet dose forms are simultaneously estimated using first and second order derivative spectrophotometric methods devised in the current study. Emtricitabine and tenofovir disoproxil Fumarate were combined to create a standard/sample, and the spectra of the absorption, first order, and second order derivatives were recorded in comparison to a reagent blank. With absorbance values of 0.639, 0.420, and 0.164, respectively, three peaks at 265 and 215 nm and one valley at 235 nm were noted in the absorption spectra. In the first order derivative spectrum, three positive peaks at 380, 325, and 260 nm and three negative peaks at 355, 280, and 225 nm were identified. The peak at 260 nm and the valley at 280 nm have the highest positive and negative amplitudes, respectively, compared to the other peaks and valleys. In the second order derivative spectrum, three peaks at 365, 290 and 250 nm with highest positive amplitude at 250 nm and three valleys at 350, 265 and 215 nm with maximum negative amplitude at 215 nm were noted. In order to validate the approach for tenofovir disoproxil fumarate and emtricitabine, positive amplitudes at 282.4 nm and negative amplitudes at 258.7 nm in the combined first derivative spectrum, respectively, were measured. Emtricitabine was validated using the amplitude of the second derivative sharp peak at 282.4 nm in the case of the second derivative method. Emtricitabine interferes with measurements of tenofovir disoproxil Fumarate at 258.7 nm, so the difference between the two amplitudes was used to validate the method for tenofovir disoproxil Fumarate. System and procedure precision RSD percentages were found to be within acceptable bounds. Accuracy trials at three spiking levels indicated that the mean recovery percent ranged from 99.4 to 100.48. The proposed methods were used to determine the Truvada assay, and it was discovered that the percent of assay for emtricitabine and tenofovir disoproxil Fumarate, respectively, was in the range of 100.75 ± 0.534 and 99.46 ± 0.671. The developed methods were found to be precise, accurate, linear and sensitive.
Item Type: | Book Section |
---|---|
Subjects: | Science Global Plos > Chemical Science |
Depositing User: | Unnamed user with email support@science.globalplos.com |
Date Deposited: | 02 Oct 2023 12:44 |
Last Modified: | 02 Oct 2023 12:44 |
URI: | http://ebooks.manu2sent.com/id/eprint/1564 |